crouse hinds on electric panel box if not do nothing You need to check the panel cover. It will tell you what breakers have been tested and approved to be used in the box. Most times it will say to use only (in this case) GE breakers. Using other breakers will void the . Nemaco offers NEMA 4 enclosures in various sizes from small boxes to large free standing cabinets for industrial applications to protect and housing electrical components in both the indoor and outdoor environments.
0 · i have a crouse
1 · crouse hinds 200 amp panel
2 · Replacements for Crouse Hinds
3 · Replacement panel for Crouse Hinds e26095 panel
4 · Replace Crouse
5 · Is this electric breaker panel safe? : r/AskElectricians
6 · Crouse Hinds panel rejection by realtor/insurance
7 · Crouse Hinds breaker compatibility
8 · Crouse
9 · Crouse
$298.50
It's a 200A Crouse Hinds panel installed in 1993 moderately loaded for an all electric home. What are your specific concerns ? First, the 200A main seems to be available from both Siemens and GE. Here's the Siemens cross reference link > http://www.sea.siemens.com/us/Products/Residential .Crouse-Hinds is not on the fire hazard list but yours is over 40 years old. Their big problem was with the 150 to 200 amp breakers but you don't have one of those. The GE breakers don't . You need to check the panel cover. It will tell you what breakers have been tested and approved to be used in the box. Most times it will say to use only (in this case) GE breakers. Using other breakers will void the .
If the panel has no rust, buss bar damage and is of adequate capacity it should be ok. If a 25 amp breaker in the panel is causing you problems you can replace it with a . Customer's panel (Crouse Hinds) label says Cr. Hinds or Bryant BR or Westinghouse breakers allowed. A supply house tells me Eaton BR will be accepted by any inspector.
I have a Crouse Hinds Panel box in my home and have a bad 60 amp 2 pole type MP circuit breaker and am not having any luck finding any. Is there a brand that will . I have a customer with a old Crouse Hinds panel, it has so many different brands of breakers in it. Starting with GE,ITE,Siemens,Bryant,CH-BR, and Murray. As far as I know .
i have a crouse
We're having some electrical work done and the electrician is recommending that we replace our electrical panel because it’s so old. It's a Crouse-Hinds "Type G Panelboard," . Your Crouse Hinds Panel has a Crouse Hinds / Murray main and the circuit breakers installed are Crouse Hinds, GE and Cutler Hammer and ITE. These Panels are not dangerous like Federal Pacific or Zinsco. If you need to replace any breakers, it is now Murray It's a 200A Crouse Hinds panel installed in 1993 moderately loaded for an all electric home. What are your specific concerns ?
First, the 200A main seems to be available from both Siemens and GE. Here's the Siemens cross reference link > http://www.sea.siemens.com/us/Products/Residential-Electrical/Pages/competitive-cross-ref.aspx Type 'MPD2200' in .
Crouse-Hinds is not on the fire hazard list but yours is over 40 years old. Their big problem was with the 150 to 200 amp breakers but you don't have one of those. The GE breakers don't belong as not listed for that panel. You need to check the panel cover. It will tell you what breakers have been tested and approved to be used in the box. Most times it will say to use only (in this case) GE breakers. Using other breakers will void the warranty on the box and the box will not be UL listed any more. Sometimes the box will say to use a like type breaker. Considering its age and being an aluminum buss panel, I'd recommend changing it. That's a Crouse-Hinds/Murray division panel. It's an older panel but I'm not aware of any inherent problems with them. It's only a 12 circuit panel with lots of tandem breakers. If the panel has no rust, buss bar damage and is of adequate capacity it should be ok. If a 25 amp breaker in the panel is causing you problems you can replace it with a Siemens or Murray 25 amp breaker as long as you feel comfortable doing the work yourself.
Customer's panel (Crouse Hinds) label says Cr. Hinds or Bryant BR or Westinghouse breakers allowed. A supply house tells me Eaton BR will be accepted by any inspector. I have a Crouse Hinds Panel box in my home and have a bad 60 amp 2 pole type MP circuit breaker and am not having any luck finding any. Is there a brand that will interchange with theirs? . read more I have a customer with a old Crouse Hinds panel, it has so many different brands of breakers in it. Starting with GE,ITE,Siemens,Bryant,CH-BR, and Murray. As far as I know only Murray and Siemens would be a ul listed replacement.
Your Crouse Hinds Panel has a Crouse Hinds / Murray main and the circuit breakers installed are Crouse Hinds, GE and Cutler Hammer and ITE. These Panels are not dangerous like Federal Pacific or Zinsco. If you need to replace any breakers, it is now Murray It's a 200A Crouse Hinds panel installed in 1993 moderately loaded for an all electric home. What are your specific concerns ? First, the 200A main seems to be available from both Siemens and GE. Here's the Siemens cross reference link > http://www.sea.siemens.com/us/Products/Residential-Electrical/Pages/competitive-cross-ref.aspx Type 'MPD2200' in .
Crouse-Hinds is not on the fire hazard list but yours is over 40 years old. Their big problem was with the 150 to 200 amp breakers but you don't have one of those. The GE breakers don't belong as not listed for that panel.
You need to check the panel cover. It will tell you what breakers have been tested and approved to be used in the box. Most times it will say to use only (in this case) GE breakers. Using other breakers will void the warranty on the box and the box will not be UL listed any more. Sometimes the box will say to use a like type breaker.
Considering its age and being an aluminum buss panel, I'd recommend changing it. That's a Crouse-Hinds/Murray division panel. It's an older panel but I'm not aware of any inherent problems with them. It's only a 12 circuit panel with lots of tandem breakers. If the panel has no rust, buss bar damage and is of adequate capacity it should be ok. If a 25 amp breaker in the panel is causing you problems you can replace it with a Siemens or Murray 25 amp breaker as long as you feel comfortable doing the work yourself. Customer's panel (Crouse Hinds) label says Cr. Hinds or Bryant BR or Westinghouse breakers allowed. A supply house tells me Eaton BR will be accepted by any inspector.
I have a Crouse Hinds Panel box in my home and have a bad 60 amp 2 pole type MP circuit breaker and am not having any luck finding any. Is there a brand that will interchange with theirs? . read more
crouse hinds 200 amp panel