After opening the outlet up, it appears that the metal box has no grounding screw and the existing grounding wires are wrapped behind the mounting screws (the box has two mounting bracket, one on the top and one on the bottom and each bracket has some space to .There are two simple ways to connect a ground screw to the box, a screw or a .If new fixture has a ground wire, then just connect grounds together with wire .
Do not use sheet-metal screws. However, this may not be necessary. The device .
no ground wire in old box
There are two simple ways to connect a ground screw to the box, a screw or a grounding clip. If there's no threaded hole for a ground screw, a clip is the easy way to go, rather than drilling and tapping the box. If new fixture has a ground wire, then just connect grounds together with wire nuts/wagos, plus to the screw in the box. Quite a few light fixtures .
Do metal junction boxes require a grounding screw with pigtail? Several Journeymen have stated that if you run metal conduit, the conduit is considered grounded, .The good news is that if your electrical box has a system of grounding wires (that run parallel to the neutral and hot wires), the electrical current will have an alternative pathway to follow if a wire connection in the main system ever . In either case if you have a grounding screw on the outlet itself IT SHOULD BE USED. Especially if you are using the metal junction box as a self-made "extension cord" .
The easiest way to upgrade an ungrounded 120V receptacle to get ground protection is to replace it with a GFCI outlet. This doesn't turn an ungrounded outlet into a grounded outlet, but it does provide protection . Plastic boxes cannot be grounded in the same way. But it’s still necessary to bring the equipment-grounding conductor into the enclosure to ground devices such as switches and receptacles. Connect the bare or green . Do not use sheet-metal screws. However, this may not be necessary. The device has metal tabs (ears) where you screw it into the box. Pay close attention - if the ears "bottom out" on the metal of the box, you do not .
metal roofs houses
After opening the outlet up, it appears that the metal box has no grounding screw and the existing grounding wires are wrapped behind the mounting screws (the box has two mounting bracket, one on the top and one on the bottom and each bracket has some space to the back of the box - see the picture).There are two simple ways to connect a ground screw to the box, a screw or a grounding clip. If there's no threaded hole for a ground screw, a clip is the easy way to go, rather than drilling and tapping the box.
If new fixture has a ground wire, then just connect grounds together with wire nuts/wagos, plus to the screw in the box. Quite a few light fixtures are not grounded, but the boxes are. Plastic fixture plus glass bulb means no electric path(usually). It is entirely possible for an electrical device to not use the ground. Especially for low-power devices, such as routers, mobile phone chargers, small lamps, and so on. In such a case, the ground wire should be taped off and left alone.
Do metal junction boxes require a grounding screw with pigtail? Several Journeymen have stated that if you run metal conduit, the conduit is considered grounded, thus a ground screw in every j-box is not required (the same answer applies if you're running MC cable).The good news is that if your electrical box has a system of grounding wires (that run parallel to the neutral and hot wires), the electrical current will have an alternative pathway to follow if a wire connection in the main system ever becomes loose or if a rodent damages the wire. In either case if you have a grounding screw on the outlet itself IT SHOULD BE USED. Especially if you are using the metal junction box as a self-made "extension cord" because if that box comes into contact with moisture getting an electric shock is a high probability.
The easiest way to upgrade an ungrounded 120V receptacle to get ground protection is to replace it with a GFCI outlet. This doesn't turn an ungrounded outlet into a grounded outlet, but it does provide protection against shock. A GFCI outlet installation does not protect equipment from power surges. Plastic boxes cannot be grounded in the same way. But it’s still necessary to bring the equipment-grounding conductor into the enclosure to ground devices such as switches and receptacles. Connect the bare or green wire directly to the green screw on the device. Do not use sheet-metal screws. However, this may not be necessary. The device has metal tabs (ears) where you screw it into the box. Pay close attention - if the ears "bottom out" on the metal of the box, you do not need that ground wire. If . After opening the outlet up, it appears that the metal box has no grounding screw and the existing grounding wires are wrapped behind the mounting screws (the box has two mounting bracket, one on the top and one on the bottom and each bracket has some space to the back of the box - see the picture).
There are two simple ways to connect a ground screw to the box, a screw or a grounding clip. If there's no threaded hole for a ground screw, a clip is the easy way to go, rather than drilling and tapping the box. If new fixture has a ground wire, then just connect grounds together with wire nuts/wagos, plus to the screw in the box. Quite a few light fixtures are not grounded, but the boxes are. Plastic fixture plus glass bulb means no electric path(usually). It is entirely possible for an electrical device to not use the ground. Especially for low-power devices, such as routers, mobile phone chargers, small lamps, and so on. In such a case, the ground wire should be taped off and left alone.
Do metal junction boxes require a grounding screw with pigtail? Several Journeymen have stated that if you run metal conduit, the conduit is considered grounded, thus a ground screw in every j-box is not required (the same answer applies if you're running MC cable).The good news is that if your electrical box has a system of grounding wires (that run parallel to the neutral and hot wires), the electrical current will have an alternative pathway to follow if a wire connection in the main system ever becomes loose or if a rodent damages the wire. In either case if you have a grounding screw on the outlet itself IT SHOULD BE USED. Especially if you are using the metal junction box as a self-made "extension cord" because if that box comes into contact with moisture getting an electric shock is a high probability. The easiest way to upgrade an ungrounded 120V receptacle to get ground protection is to replace it with a GFCI outlet. This doesn't turn an ungrounded outlet into a grounded outlet, but it does provide protection against shock. A GFCI outlet installation does not protect equipment from power surges.
Plastic boxes cannot be grounded in the same way. But it’s still necessary to bring the equipment-grounding conductor into the enclosure to ground devices such as switches and receptacles. Connect the bare or green wire directly to the green screw on the device.